Imaging Systems

Ingenia Prodiva 1.5T CX

Accelerate patient throughput with a simplified Breeze workflow

Find similar products

Support your clinical decisions by leveraging our imaging solutions built on proven dStream digital broadband technology, present in over 2000 installations worldwide. Accelerate patient throughput with a simplified Breeze Workflow. An intuitive user interface enhanced by highly guided and standardized examination procedures helps you perform routine MRI exams from day one. And with low installation and siting expenses, continuous uptime support and easy upgrades, you can continue to enhance your possibilities.

Specifications

Magnet system
Magnet system
Magnet weight
  • 2700 kg
Open bore diameter
  • 60 cm
Maximum FOV
  • up to 50 cm (X, Y), up to 45 cm (Z)
Typical homogeneity VRMS at 40cm DSV
  • ≤ 0.9 ppm
Cryogen boil-off rate under regular scanning conditions
  • 0 l/hr
Stellar GP gradient
Stellar GP gradient
Max. amplitude for each axis
  • 33 mT/m
Max. slew rate for each axis
  • 120 T/m/s
Resolution parameters
Resolution parameters
Max. scan matrix
  • 1024
Highest in-plane resolution
  • 5 μm
Max. number of slices
  • 1024 (2048 option)
RF transmit
RF transmit
RF transmit
  • Yes
Output power
  • 18 kW
dStream RF receive
dStream RF receive
Number of independent receive channels
  • Channel independent
Location of analog-to-digital converter (ADC)
  • Inside the coil (NVS)/At the patient table (Anterior)
Signal chain from coil to reconstructor
  • Fully digital
Signal chain from coil electronics to connector
  • Digital
Signal chain from coil electronics to magnet
  • Digital
Signal chain from coil electronics to reconstructor
  • Digital
Patient environment
Patient environment
Patient aperture
  • 60 cm
Flare on both ends
  • Yes
Wireless patient physiological synchronization
  • Yes
Various acoustic noise reduction solutions
  • Yes
Breeze workflow
Breeze workflow
Breeze Posterior coil
  • Yes
Breeze Anterior coils (optional)
  • Yes
Breeze connectors
  • Yes
Breeze dS Interface
  • Yes
Breeze patient table
  • Yes
Breeze coil storage (optional)
  • Yes
iPatient efficiency assistance
iPatient efficiency assistance
SmartStart
  • Yes
SmartSelect
  • Yes
SmartExam (optional)
  • Yes
SmartLine (package dependent)
  • Yes
SmartLink (package dependent)
  • Yes
Site Planning
Site Planning
Minimum siting requirement (Scan room, Technical room and control room)
  • 25 m²
Minimum Ceiling height
  • 2.35 m²
  • 1. Based on internal study comparing workflow with Achieva.
  • 2. Based on an internal study comparing workflow in a mix of brain, spine, MSK and body applications with the Achieva MR system.
  • 3. Dependent on contract entitlement and local availability.
  • 4. Normal operation is defined as typical scanning performed with uninterrupted availability of electricity, magnet cooling and excluding service actions.
  • This content is not intended for a US audience.